Skip to main content
SKU
RXSOL-40-4008-210

Title
BIOCIDE for Closed Loop Chilled Water

<h1>
Non-Oxidizing Biocide for Cooling Water Systems – Effective Microbial Control</h1>
<p>
<strong>Non-oxidizing biocide for cooling water systems</strong> is a specialized water-treatment chemical designed to control and reduce the growth of <strong>bacteria, fungi, algae, and other microorganisms</strong> in industrial and commercial water systems. It is commonly used in <strong>closed-loop cooling circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems</strong>.</p>
<p>
Microbial growth can result in biofilm formation, slime deposits, fouling, unpleasant odors, reduced heat-transfer efficiency, and microbiologically influenced corrosion (MIC). Regular treatment with a suitable non-oxidizing biocide helps maintain cleaner water systems and supports efficient cooling-system operation.</p>
<p style="text-align: justify;">
<br />
<span style="font-size:14px;">Very effective controler of BACTERIA and corrosion from closed loop chilled water system.</span></p>
<p style="text-align: justify;">
<span style="font-size:14px;">BIOCIDE for Closed Loop Chilled Water is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.</span></p>
<p style="text-align: justify;">
<span style="font-size:14px;">It is a enviromentally safe and versatile anti microbial and a powerful anti oxidant, When it dissolved in water, it disintegrates to water, oxygen and carbon dioxide. All these degradation products are non toxic. It is a very powerful oxidant, whose oxidation potential outranges that of chlorine and chlorine oxides.</span></p>

Category
Cooling Water Chemical-43

Product Remarks

Remarks

<table border="0" cellpadding="1" cellspacing="10">
<tbody>
<tr>
<td>
<h2>
Description</h2>
<hr />
<p>
BIOCIDE for Closed Loop chilled water is a high performance, broad spectrum organic biocide scientifically formulated for the treatment of open re-circulating cooling systems. RXSOL-40-4008-210 is a superior quality treatment that is ideal for the control of bacteria, fungi and algae in open re-circulating cooling systems and evaporative condensers. RXSOL-40-4008-210 is a proven high performing product that is that can be used where exceptional performance is critical.</p>
<p>
RXSOL-40-4008-210 is low foaming and effective over a broad pH range.</p>
<p>
 </p>
<h2>
Application and Dosage</h2>
<hr />
<p>
Typically RXSOL-40-4008-210 should be dosed to give 80 ppm (80 g per 1000 lt). Dose at 160 ppm (160 g per 1000 Lt) for heavily fouled systems. Do not mix with other chemicals. Can be dosed by hand or through automatic dosing equipment. It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use. For further technical assistance concerning RXSOL-40-4008-210 please contact us.</p>
</td>
<td>
<h2>
Specification</h2>
<hr />
<table border="0">
<tbody>
<tr>
<td>
Form:</td>
<td>
Liquid</td>
</tr>
<tr>
<td>
Colour:</td>
<td>
Colourless</td>
</tr>
<tr>
<td>
pH:</td>
<td>
3 – 5</td>
</tr>
<tr>
<td>
Specific gravity:</td>
<td>
>1.2</td>
</tr>
<tr>
<td>
Solubility in water:</td>
<td>
Completely miscible</td>
</tr>
<tr>
<td>
Boiling point:</td>
<td>
>100 oC</td>
</tr>
<tr>
<td>
Decomposition temp:</td>
<td>
Decomposes at boiling point</td>
</tr>
</tbody>
</table>
<p>
 </p>
<h2>
Features and Benefits</h2>
<hr />
<ul>
<li>
High performance broad spectrum biocide</li>
<li>
Contains glutaraldehyde</li>
<li>
Ideal for open re-circulating cooling systems and evaporative condensers</li>
<li>
Effective against a wide range of bacteria, algae and slimes</li>
<li>
Effective against Legionella strains, the causitive organism of Legionnaires’ disease</li>
<li>
Effective against sulphate reducing bacteria</li>
<li>
Low foaming</li>
<li>
Effective over broad pH range</li>
<li>
Can be dosed in conjunction with other organic biocides to help clean up badly fouled systems</li>
</ul>
</td>
</tr>
</tbody>
</table>

Field Note

Note

<h2>
What is a Non-Oxidizing Biocide?</h2>
<p style="text-align: justify;">
<span style="font-size:14px;">A <strong>non-oxidizing biocide</strong> controls microorganisms through chemical mechanisms that do not depend primarily on oxidation. Unlike oxidizing biocides such as chlorine or bromine-based treatments, non-oxidizing biocides can provide targeted microbial control and are often used as part of a broader cooling-water treatment program.</span></p>
<p style="text-align: justify;">
<span style="font-size:14px;">The selection of an appropriate biocide depends on the system design, water chemistry, microbial population, operating temperature, materials of construction, and regulatory requirements.</span></p>
<p>
<br />
<br />
Form    :::::  Liquid<br />
Colour ::::   Clear Colourless<br />
Odour  :::: Strong Pungent<br />
pH ( 1% solution ) :::: 1.0 -2.0</p>

Technical Specifications

<h2>
Specification</h2>
<hr />
<table border="0">
<tbody>
<tr>
<td>
Form:</td>
<td>
Liquid</td>
</tr>
<tr>
<td>
Colour:</td>
<td>
Colourless</td>
</tr>
<tr>
<td>
pH:</td>
<td>
3 – 5</td>
</tr>
<tr>
<td>
Specific gravity:</td>
<td>
>1.2</td>
</tr>
<tr>
<td>
Solubility in water:</td>
<td>
Completely miscible</td>
</tr>
<tr>
<td>
Boiling point:</td>
<td>
>100 oC</td>
</tr>
<tr>
<td>
Decomposition temp:</td>
<td>
Decomposes at boiling point</td>
</tr>
</tbody>
</table>

Application

<h2>
Applications of Cooling Water Biocide</h2>
<h3>
1. Closed-Loop Cooling Systems</h3>
<p style="text-align: justify;">
Closed-loop cooling systems can experience microbial contamination, particularly when water quality, temperature, or system conditions support microbial growth. A suitable non-oxidizing biocide can help control bacteria and fungi and reduce biological fouling.</p>
<h3>
2. Recirculating Cooling Towers</h3>
<p style="text-align: justify;">
Cooling towers continuously recirculate water, creating conditions that can support microbial growth. Biocide treatment helps control <strong>algae, bacteria, fungi, slime, and biofilm</strong>, supporting efficient heat transfer and cleaner tower operation.</p>
<h3>
3. Air Washers</h3>
<p style="text-align: justify;">
Air-washing systems use circulating water and can become susceptible to microbial contamination. A properly selected biocide can help control biological growth and maintain cleaner circulating water.</p>
<h3>
4. Heat Exchangers</h3>
<p style="text-align: justify;">
Microbial deposits and biofilm can accumulate on heat-transfer surfaces and reduce heat-transfer efficiency. Biocide treatment can form part of a preventive water-treatment program to control biological fouling.</p>
<h3>
5. Industrial Process Water Systems</h3>
<p style="text-align: justify;">
Non-oxidizing biocides are also used in selected industrial water circuits where microbial growth can affect equipment performance, water quality, or production processes.</p>
<div>
 </div>
<p>
marine / Industrial circulating cooling water for both open and closed loops ( including food contact )<br />
Milk & Dairy products processing and packaging plants.<br />
Wineries, vineyards and breweris plant<br />
Meat, Seafood, poultary and vegetable processing plants<br />
Cleaning, sanitising and disinfections of UF & RO membranes<br />
Waste water treatment ( odour control agent, disinfectant and cleaner )<br />
Hospital & Health care facilities, veterinary clinics<br />
Hatcheries and egg processing unit.<br />
Dish and table ware sanitizer</p>

Dose

<br />

Useful Area

<p>
Key Benefits</p>
<div id="cke_pastebin">
<p>
A properly selected non-oxidizing cooling-water biocide can provide:</p>
<ul>
<li>
<p>
Effective control of bacteria</p>
</li>
<li>
<p>
Control of fungi and yeast</p>
</li>
<li>
<p>
Algae control</p>
</li>
<li>
<p>
Reduction of slime and biofilm formation</p>
</li>
<li>
<p>
Improved cooling-water hygiene</p>
</li>
<li>
<p>
Support for efficient heat transfer</p>
</li>
<li>
<p>
Reduced risk of microbiological fouling</p>
</li>
<li>
<p>
Compatibility with selected water-treatment programs</p>
</li>
<li>
<p>
Useful performance in closed and recirculating systems</p>
</li>
</ul>
<h2>
Why Microbial Control is Important in Cooling Systems</h2>
<p>
Microorganisms can multiply rapidly under favorable conditions. Once established, they may produce extracellular polymeric substances that contribute to biofilm and slime formation.</p>
<p>
Biological fouling can:</p>
<ol>
<li>
<p>
Reduce heat-transfer efficiency</p>
</li>
<li>
<p>
Increase pressure drop and flow resistance</p>
</li>
<li>
<p>
Promote under-deposit corrosion</p>
</li>
<li>
<p>
Contribute to microbiologically influenced corrosion</p>
</li>
<li>
<p>
Increase cleaning and maintenance requirements</p>
</li>
<li>
<p>
Reduce overall cooling-system efficiency</p>
</li>
</ol>
<p>
For these reasons, microbial control is an important component of a comprehensive cooling-water treatment program.</p>
<h2>
Non-Oxidizing vs. Oxidizing Biocides</h2>
<p>
Both oxidizing and non-oxidizing biocides can be useful in cooling-water treatment, but their mechanisms differ.</p>
<p>
Oxidizing biocides control microorganisms primarily through oxidation reactions and may include chlorine-, bromine-, or other oxidizing chemistries.</p>
<p>
Non-oxidizing biocides work through other mechanisms that interfere with microbial cellular functions. They are often selected when a particular microbial population needs targeted control or when an oxidizing program is not suitable for the application.</p>
<p>
In some systems, oxidizing and non-oxidizing biocides may be used in a carefully designed treatment program to improve overall microbial control.</p>
<h2>
Cooling Water Biocide Treatment Program</h2>
<p>
A successful cooling-water treatment program normally considers more than biocide addition alone. Important factors may include:</p>
<ul>
<li>
<p>
Water quality</p>
</li>
<li>
<p>
pH</p>
</li>
<li>
<p>
Temperature</p>
</li>
<li>
<p>
Microbial counts</p>
</li>
<li>
<p>
System volume</p>
</li>
<li>
<p>
Blowdown rate</p>
</li>
<li>
<p>
Circulation rate</p>
</li>
<li>
<p>
Organic loading</p>
</li>
<li>
<p>
Biofilm condition</p>
</li>
<li>
<p>
Corrosion-control requirements</p>
</li>
<li>
<p>
Compatibility with other treatment chemicals</p>
</li>
</ul>
<p>
The correct dosage and treatment frequency should be established according to the specific product technical data sheet, water-system conditions, and qualified water-treatment guidance.</p>
<h2>
Non-Oxidizing Biocide Supplier</h2>
<p>
When sourcing a non-oxidizing biocide for cooling water systems, industrial users should evaluate product efficacy, compatibility, technical documentation, regulatory status, and supplier support.</p>
<p>
A reliable supplier should be able to provide:</p>
<ul>
<li>
<p>
Technical Data Sheet (TDS)</p>
</li>
<li>
<p>
Safety Data Sheet (SDS)</p>
</li>
<li>
<p>
Certificate of Analysis (COA), where applicable</p>
</li>
<li>
<p>
Recommended application and dosage guidance</p>
</li>
<li>
<p>
Packaging options</p>
</li>
<li>
<p>
Batch traceability</p>
</li>
<li>
<p>
Technical support</p>
</li>
</ul>
<h2>
Safety and Handling</h2>
<p>
Biocides are active chemicals and must be handled responsibly. Always review the current Safety Data Sheet (SDS) before use. Appropriate personal protective equipment should be worn, and the product should be stored and handled according to the manufacturer's instructions.</p>
<p>
Biocide selection and dosing should also consider applicable local environmental and discharge requirements.</p>
<h2>
Conclusion</h2>
<p>
Non-oxidizing biocide for cooling water systems is an important component of microbial-control programs for closed-loop circuits, recirculating cooling towers, air washers, heat exchangers, and industrial water systems.</p>
<p>
By controlling bacteria, fungi, algae, and biofilm-forming microorganisms, an appropriate biocide treatment can help reduce biological fouling, support heat-transfer efficiency, and protect cooling-system performance.</p>
<p>
For industrial applications, the best results are achieved when the biocide is selected and dosed according to the system's water chemistry, microbial conditions, operating parameters, and treatment objectives.</p>
</div>

Locations

<p style="text-align: justify;">
BIOCIDE for Closed Loop chilled water is Non oxidizing Microbiocide for bacterial control in open re-circulating system of cooling loop. We are Biocide for cooling water manufacturer, exporter and supplier in Mumbai, Surat, Gandhidham GIDC, Mundra, Manglore, Chennai, Visakhapatnam, Kolkata, Fujairah, Dubai, Sharjah, Abudhabi, Ajman - UAE - Middle East,  Barka - Muscat - Oman.</p>

Keywords

<p style="text-align: justify;">
<span style="text-align: justify;">Biocide for Cooling Water System, Non-Oxidizing Biocide, Cooling Tower Biocide, Cooling Water Treatment Chemical, Non-Oxidizing Biocide Supplier, Cooling Water Biocide Supplier, Biocide for Closed Loop Cooling System, Biocide for Recirculating Cooling Tower, Air Washer Biocide, Industrial Water Treatment Biocide, Bacteria Control Biocide, Algae Control Chemical, Fungicide for Cooling Water, Cooling Tower Microbial Control, Cooling System Biocide, Industrial Biocide Supplier, Water Treatment Chemicals, Microbial Control Chemical, Biofilm Control Chemical, Cooling Water Treatment Chemicals.</span></p>

About

We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.

Contact info

logo

Tank Cleaner provides marine tank cleaning, degassing, and gas-freeing services for chemical tankers, oil tankers, and gas carriers calling at Indian ports.

Featured Post